文献知网节

Graphene-modified CPE as a disposable electrochemical sensor for rapid determination of fluoranthene

Wenhan Zhong1Xiaoying Yan2Tao Han3Mengfan Wu1Zhihao Xu1Ying Wang1Xiaohong Jin1

1. Zhejiang Light Industrial Products Inspection and Research Institute2. Zhonghang Monitoring & Testing Research Institute Co., Ltd3. JUSHI Group Co., Ltd

摘要:A disposable electrochemical sensor(ES) was developed by embellishing graphene on carbon paste electrode(CPE), and the electrocatalytic activity of fluoranthene(Frt) was investigated. An anodic peak of Frt-acetonitrile-NaClO4 appeared at 1.6 V based on the cyclic voltammetry. The peak current of Frt at graphene-modified CPE was increased compared with that of unmodified electrode. The differential pulse voltammetry revealed a linear relationship between peak current and Frt concentration within 2–140 ng mL-1, and the LOD was calculated to be 0.95 ng mL-1. Also, the ES method was effective for rapid determination of Frt in black rubbers on modified CPE.
会议名称:

第四届环境与地球科学国际学术研讨会

会议时间:

2021-07-17

会议地点:

中国浙江杭州

  • 专辑:

    工程科技Ⅰ辑; 信息科技

  • 专题:

    环境科学与资源利用; 自动化技术

  • DOI:

    10.26914/c.cnkihy.2021.064330

  • 分类号:

    X830;TP212.2

  • 手机阅读
    即刻使用手机阅读
    第一步

    扫描二维码下载

    "移动知网-全球学术快报"客户端

    第二步

    打开“全球学术快报”

    点击首页左上角的扫描图标

    第三步

    扫描二维码

    手机同步阅读本篇文献

  • HTML阅读
  • CAJ下载
  • PDF下载

下载手机APP用APP扫此码同步阅读该篇文章

温馨提示:阅读CAJ格式原文,请使用CAJ浏览器

页码:79-85 页数:7 大小:836k