摘要:For recent decades,a considerable amount of 99 mTc has been stimulated for diagnosis radiopharmaceuticals because of its physical advantages.The increase in the use of 99 mTc makes naturally more chances of internal exposure for not only patients but also medical workers.The patient internal exposure by an intravenous injection has been assessed relatively well with the reports of International Commission on Radiological Protection(ICRP) or Medical Internal Radiation Dose(MIRD).However,there are few studies which can support its accurate assessment for medical worker who treats 99 mTc.In spite of the absence of information,the physiological information of each 99 mTc-labelled compound for patient,provided by ICRP.can be used optionally for worker exposure because the behaviors after uptake to blood are similar for patient and worker.Using the data,in this study,the data for bioassay were given as the intake whole-body retention and urinary excretion function.We selected the two most frequently used 99 mTc-labelled compounds based on statistical data;99 mTc-phosphonate,pertechnetate.The data of the Human Alimentary Tract Model(HATM,publication 100) and the revised Human Respiratory Tract Model(revised HRTM,OIR) were used for compartment models which depict the physiological behavior in body after intake.In case of 99 mTc-phosphonate,we adopted the systemic model for patient intake described in ICRP publication 53 based on the assumption that the behaviors after uptake to blood are similar for patient and worker.On the other hand,recent updated systemic model in OIR report could be directly adopted for pertechnetate.We used Birchall’s algorithm for calculation and developed the module which could calculate the retention amounts in each compartment at given time by MATLAB.In addition,we fitted the functions as sum of exponential terms using ORIGIN and the fitting coefficients were provided.We also could calculate the committed dose coefficients for each compound using SAF values for photons provided by Cristy and Eckerman.The results in this study will be useful to estimate the intake and effective dose for medical field.
  • DOI:

    10.13538/j.1001-8042/nst.25.S010302

  • 专辑:

  • 专题:

  • 分类号:

    R730.55

  • 手机阅读
    即刻使用手机阅读
    第一步

    扫描二维码下载

    "移动知网-全球学术快报"客户端

    第二步

    打开“全球学术快报”

    点击首页左上角的扫描图标

    第三步

    扫描二维码

    手机同步阅读本篇文献

  • HTML阅读
  • CAJ下载
  • PDF下载

下载手机APP用APP扫此码同步阅读该篇文章

温馨提示:阅读CAJ格式原文,请使用CAJ浏览器

下载:3 页码:19-23 页数:5 大小:514K

引文网络
  • 参考文献
  • 引证文献
  • 共引文献
  • 同被引文献
  • 二级参考文献
  • 二级引证文献
相关推荐
  • 相似文献
  • 读者推荐
  • 相关基金文献
  • 相关法规
  • 关联作者
  • 相关视频